Symposium Conference Proceedings


Recent Technology Advances In X-Ray Inspection For Yield Improvement

Authors: Keith Bryant and Frieldhelm Maur
Company: SMT Solutions and YXLON Limited
Date Published: 4/12/2016   Conference: Symposium


Abstract: Taking x-ray images goes back over 100 years. Since then, there have been numerous advances in terms of xray tube and x-ray detector technology and these have been increasingly applied into helping with the manufacturing of electronic components and assemblies, as well as in their failure analysis.

More recently, this has been rapidly driven by the continued reduction in board, device and feature size and the movement to using newer, lower density materials within the structures, such as copper wire replacing gold wire as the interconnection material of choice within components. In order to meet these challenges and those in the future, there have been a number of recent key improvements to the vital components within x-ray systems. In particular, there is a new x-ray tube type that permits high magnification inspection at improved resolution, yet retains high tube power under these conditions, allowing good x-ray flux for inspection of the smallest features.

There is also the availability of new and improved x-ray detectors (both image intensifiers and Digital Flat Panels) that are now specifically designed for electronics applications, rather than hand-me-downs from the needs of the medical market, which are able to take best advantage of these tube developments. The choice of available technologies, however, means selecting the tube/detector combination, which is optimum for a particular electronics inspection application, is no longer so clear-cut. For example, one configuration may provide certain benefits that are applicable for one area of electronics inspection, whilst being less valid for others. This paper will review the various x-ray tube and detector types that are available and explain the implications of these choices for electronics inspection in terms of what they provide for inspection regarding image resolution, magnification, tube power, detector pixel size and the effects of detector radiation damage, amongst others. It will also suggest optimum configurations for the main electronics inspection tasks required today. The increasing use of copper bond wires to replace the gold wire used for many years is one example where the type of flat panel technology can have a significant effect on the resultant images.

In addition to these demands we are now seeing pressure from companies to use off line or At-Line systems as an integral part of their quality management system. This is happening in areas from AQL inspection to feedback to SPC systems.

These technology advances are key to providing a solution here, as high quality images, fast, easy operation are key to providing the operator with accurate information, as fast as possible. This gives fast feedback and allows for almost real time inspection giving real yield improvement potential.



Members download articles for free:

Not a member yet?

What else do you get when you join SMTA? Read about all of the benefits that go along with membership.

Notice: Sharing of articles is restricted to just your immediate work group. Downloaded papers should not be stored on an external network or shared on the internet.


Back


SMTA Headquarters
6600 City West Parkway, Suite 300
Eden Prairie, MN 55344 USA

Phone +1 952.920.7682
Fax +1 952.926.1819