Determination of Total Halogen Content in Halogen-Free Fluxes by Inductively Coupled Plasma and Some Limitations of Ion Chromatography

Authors: Christopher J. Pontius, George Kraeger, Ron Lasky, Ph.D., P.E.
Company: Indium Corporation
Date Published: 9/27/2015   Conference: SMTA International


Abstract: Brominated flame retardants (BFRs) are coming under heavy scrutiny due to increasing evidence of the risks they pose to the environment and human health. Therefore, it is important for industrial quality laboratories to follow robust methods to assure commercial products meet the safety requirements established by the governing bodies of the world. Currently, the most common method to determine halogen content is oxygen combustion, followed by ion chromatography. The oxygen combustion test is widely established in environmental as well as in industrial laboratories. One current accepted test method, EN14582, may under-report bromine and chlorine content by as much as 65%. The use of inductively coupled plasma (ICP) methods of detection appears to resolve this discrepancy. Flux marketed as "zero intentionally-added halogens" was combusted in a bomb calorimeter vessel under 30atm of high-purity oxygen in the presence of 25ml of water. The resultant solution was analyzed using both ion chromatography (IC) and ICP. The flux was found to contain <10ppm of each element using both techniques. Samples were then spiked using a common flux additive containing chlorine and bromine, combusted in the same manner, and analyzed. At a low concentration (15ppm Br, 6ppm Cl), the average %recovery of Br was 60.7% by IC and 100.8% by ICP; the %recovery of Cl was 109.5% by IC and 84.8% by ICP. At a moderate concentration (150ppm Br, 65ppm Cl), the %recovery of Br was 25.5% by IC and 86.9% by ICP; the %recovery of Cl was 81.8% by IC and 104.2% by ICP. The effect of pH and buffering capacity of the absorbing solution was explored by ICP in an attempt to optimize the sequestration of Cl and Br in the solution as stable oxyanions; however, the results of hypothetically optimal solutions were no more accurate than those using analytical water as the absorbing solution. Additionally, thirty samples of flux containing 275ppm intentionally-added organic bromine were combusted and analyzed using the techniques described. The average % recovery of bromine by IC was 64.3% and 105.1% by ICP.

Key Words: 

Halogen, halogen content, measuring halogen



Members download articles for free:

Not a member yet?

What else do you get when you join SMTA? Read about all of the benefits that go along with membership.

Notice: Sharing of articles is restricted to just your immediate work group. Downloaded papers should not be stored on an external network or shared on the internet.


Back


SMTA Headquarters
6600 City West Parkway, Suite 300
Eden Prairie, MN 55344 USA

Phone +1 952.920.7682
Fax +1 952.926.1819